SECONDARY
Engineering
Control
(SEC)
For BUD > 12 hrs
ENGINEERING CONTROL REQUIREMENTS
for USP-797 and USP-800 Compliance
ALSO AVAILABLE FROM ESCO
Sterile Non-Hazardous
Cleanroom Pass Boxes
Non-Sterile Hazardous
Downflow Booth
Sterile Hazardous
503B cGMP Isolators
PRIMARY
Engineering
Control
(PEC)
Esco Models:
LHG (Horizontal): General compounding
LVG (Vertical): Put large machine inside
Esco Models:
PW1 (Compact): Single exhaust HEPA
ADC (Full-sized): Double exhaust HEPA
Esco Model:
DFB: Downflow Booth
Esco Models:
AC2 (Compact): Low ceiling, Mobile labs
LA2 (Full-sized): Best comfort & safety
DRUG TYPE
USP 797: Applies to Non-hazardous and Hazardous Drugs
USP 800: Additional Requirements for Hazardous Drugs
Horizontal Laminar Flow
Cabinet
Powder Weighing Station
with Ducting
Class II A2 Biosafety
Cabinet w/Ducting
Esco Models:
EPB-SS: Passbox, Full Stainless Steel
BIOPASS: Passbox, with H2O2 Decon
Esco Models:
GPPI: General Processing Isolator
ACTI: Aseptic Containment Isolator
215-441-9661 • Horsham, PA, USA • ETI.Admin@escolifesciences.com • www.escolifesciences.com
Compounding
Ventilated
Enclosure
Biosafety
Cabinet,
Ducted
Laminar
Flow
Cabinet
ISO 7 buffer
12 ACPH
0.01-0.03 “WG
neg. pressure
ducted
ISO 7 buffer
30 ACPH
0.02 “WG
positive
pressure
ISO 8 ante
20 ACPH
0.01 “WG
positive
pressure
ISO 7 buffer
30 ACPH
0.01-0.03 “WG
neg. pressure
ducted
ISO 7 ante
30 ACPH
0.02 “WG
positive
pressure